- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Industry linear dimming
- ►
- LCI 100 W o4a sl PRE (Industry)
Driver LCI 100W 200–850mA 300V o4a sl PRE (INDUSTRY)
premium series non-SELV
Product description
- NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
- Constant current built-in LED driver, particularly suitable for industrial applications in tough environments with elevated ambient temperatures such as cold warehouses or factories
- Dimming range 1 to 100 %
- Output current adjustable between 200 – 850 mA
- Max. output power 100 W
- Suitable for mains voltage peaks (burst/surge) up to 4 kV
- Expanded temperature range of -40 ... +70 °C
- Nominal lifetime up to 100,000 h (at ta 60 °C)
- 8 years guarantee
Housing properties
- White slim metal casing
- Type of protection IP20
Interfaces
- one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION V2)
- ready2mains (configuration and dimming via mains)
- Terminal blocks: 0° push terminals
Functions
- Adjustable output current in 1-mA-steps (I-SELECT resistor or eD)
- Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
- Constant light output function (CLO)
- Power-up fading at AC
- Intelligent Temperature Guard (overtemperature protection)
- Intelligent Voltage Guard (overvoltage and undervoltage monitoring)
- Protective features (overtemperature, short-circuit, overload, no-load, input voltage range)
- Suitable for emergency escape lighting systems acc. to EN 50172
Benefits
- Application-oriented operating window for maximum compatibility
- Best energy savings due to low stand-by losses
- Flexible configuration via DALI, ready2mains and I-SELECT 2
- Extended vibration damping
- Increased safety through robust design and advanced testing under extreme test conditions
- High reliability through the selection of exclusive components
Typical applications
- For linear/area lighting in industry applications
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LCI 100/200-850/300 o4a sl PRE | 28002052 | 10 pc(s). | 550 pc(s). | 0.324 kg |
- Luminaire types:
-
-
-
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. rated current (at 230 V, 50 Hz, full load) (1) (2) | 470 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 84 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 250 µA |
Max. input power | 106.8 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 95 % |
λ (at 230 V, 50 Hz, full load) | 0.98 |
Typ. power consumption on stand-by (3) | < 0.25 W |
Typ. input current in no-load operation | 77 mA |
Typ. input power in no-load operation | 0.52 W |
In-rush current (peak / duration) | 17.3 A / 164 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 4.3 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Starting time (DC mode) | < 0.4 s |
Switchover time (AC/DC) (4) | < 0.4 s |
Turn off time (at 230 V, 50 Hz, full load) | < 2.2 ms |
Output current tolerance (1) (5) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 30 % |
Output LF current ripple (< 120 Hz) | ± 2 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 350 V |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 4 kV |
Mains surge capability (between L/N - PE) | 4 kV |
Surge voltage at output side (against PE) | 4 kV |
Type of protection | IP20 |
Lifetime | up to 100,000 h |
Guarantee | 8 Year(s) |
Dimensions L x W x H | 360 x 30 x 28 mm |
Specific technical data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Type | Output current (1) (2) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | Ambient temperature ta | I-SELECT 2 resistor value (3) |
LCI 100/200-850/300 o4a sl PRE | 200 mA | 80 V | 300 V | 60 W | 64.1 W | 290 mA | 80 °C | -40 ... +70 °C | – |
LCI 100/200-850/300 o4a sl PRE | 250 mA | 80 V | 300 V | 75 W | 79.1 W | 319 mA | 80 °C | -40 ... +70 °C | 20.00 kΩ |
LCI 100/200-850/300 o4a sl PRE | 300 mA | 80 V | 300 V | 90 W | 94.6 W | 348 mA | 80 °C | -40 ... +70 °C | 16.67 kΩ |
LCI 100/200-850/300 o4a sl PRE | 350 mA | 80 V | 286 V | 100 W | 105.1 W | 377 mA | 80 °C | -40 ... +70 °C | 14.29 kΩ |
LCI 100/200-850/300 o4a sl PRE | 400 mA | 80 V | 250 V | 100 W | 105.2 W | 406 mA | 80 °C | -40 ... +70 °C | 12.50 kΩ |
LCI 100/200-850/300 o4a sl PRE | 450 mA | 80 V | 222 V | 100 W | 105.2 W | 436 mA | 80 °C | -40 ... +70 °C | 11.11 kΩ |
LCI 100/200-850/300 o4a sl PRE | 500 mA | 80 V | 200 V | 100 W | 105.6 W | 465 mA | 80 °C | -40 ... +70 °C | 10.00 kΩ |
LCI 100/200-850/300 o4a sl PRE | 550 mA | 80 V | 182 V | 100 W | 105.7 W | 465 mA | 81 °C | -40 ... +70 °C | 9.09 kΩ |
LCI 100/200-850/300 o4a sl PRE | 600 mA | 80 V | 167 V | 100 W | 105.9 W | 466 mA | 81 °C | -40 ... +70 °C | 8.33 kΩ |
LCI 100/200-850/300 o4a sl PRE | 650 mA | 80 V | 154 V | 100 W | 106.1 W | 467 mA | 81 °C | -40 ... +70 °C | 7.69 kΩ |
LCI 100/200-850/300 o4a sl PRE | 700 mA | 80 V | 143 V | 100 W | 106.2 W | 467 mA | 81 °C | -40 ... +70 °C | 7.14 kΩ |
LCI 100/200-850/300 o4a sl PRE | 750 mA | 80 V | 133 V | 100 W | 106.4 W | 468 mA | 82 °C | -40 ... +70 °C | 6.67 kΩ |
LCI 100/200-850/300 o4a sl PRE | 800 mA | 80 V | 125 V | 100 W | 106.6 W | 469 mA | 82 °C | -40 ... +70 °C | 6.25 kΩ |
LCI 100/200-850/300 o4a sl PRE | 850 mA | 80 V | 118 V | 100 W | 106.8 W | 470 mA | 82 °C | -40 ... +70 °C | 0.00 kΩ |
Further information
- FAQ – LED systems (http://www.ready2mains.eu/com/en/faq-led.asp)
- Reference projects (http://www.ready2mains.eu/com/en/reference-projects.asp)
- Environmental declarations (http://www.ready2mains.eu/com/en/environmental-declarations.asp)
- Tender text (http://www.ready2mains.eu/com/en/tender.asp)
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |
I-SELECT 2 PLUG PRE / EXC Accessories
Product description
- Ready-for-use resistor to set output current value
- Compatible with LED driver featuring I-select 2 interface; not compatible with I-SELECT (generation 1)
- Resistor is base insulated
- Resistor power 0.25 W
- Current tolerance ± 2 % additional to output current tolerance
- Compatible with LED driver series PRE and EXC
Example of calculation
- R [kΩ] = 5 V / I_out [mA] x 1000
- E96 resistor value used
- Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base insulation necessary
- When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data | |||||||
---|---|---|---|---|---|---|---|
Type | Article number | Colour | Marking | Current | Resistor value | Packaging, bag | Weight per pc. |
I-SELECT 2 PLUG 200MA BL | 28001104 | Blue | 0200 mA | 200 mA | 24.90 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 225MA BL | 28001105 | Blue | 0225 mA | 225 mA | 22.10 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 250MA BL | 28001106 | Blue | 0250 mA | 250 mA | 20.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 275MA BL | 28001107 | Blue | 0275 mA | 275 mA | 18.20 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 300MA BL | 28001108 | Blue | 0300 mA | 300 mA | 16.50 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 325MA BL | 28001109 | Blue | 0325 mA | 325 mA | 15.40 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 350MA BL | 28001110 | Blue | 0350 mA | 350 mA | 14.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 375MA BL | 28001111 | Blue | 0375 mA | 375 mA | 13.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 400MA BL | 28001112 | Blue | 0400 mA | 400 mA | 12.40 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 425MA BL | 28001251 | Blue | 0425 mA | 425 mA | 11.80 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 450MA BL | 28001113 | Blue | 0450 mA | 450 mA | 11.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 475MA BL | 28001252 | Blue | 0475 mA | 475 mA | 10.50 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 500MA BL | 28001114 | Blue | 0500 mA | 500 mA | 10.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 525MA BL | 28001960 | Blue | 0525 mA | 525 mA | 9.53 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 550MA BL | 28001115 | Blue | 0550 mA | 550 mA | 9.09 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 600MA BL | 28001116 | Blue | 0600 mA | 600 mA | 8.25 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 650MA BL | 28001117 | Blue | 0650 mA | 650 mA | 7.68 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 700MA BL | 28001118 | Blue | 0700 mA | 700 mA | 7.15 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 750MA BL | 28001119 | Blue | 0750 mA | 750 mA | 6.65 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 800MA BL | 28001120 | Blue | 0800 mA | 800 mA | 6.19 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 850MA BL | 28001121 | Blue | 0850 mA | 850 mA | 5.90 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Blue | MAX | MAX | 0.00 kΩ | 10 pc(s). | 0.001 kg |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
I-SELECT 2 PLUG 200MA BL | 28001104 | CAD (712.6 KB) |
I-SELECT 2 PLUG 225MA BL | 28001105 | CAD (712.6 KB) |
I-SELECT 2 PLUG 250MA BL | 28001106 | CAD (712.6 KB) |
I-SELECT 2 PLUG 275MA BL | 28001107 | CAD (712.6 KB) |
I-SELECT 2 PLUG 300MA BL | 28001108 | CAD (712.6 KB) |
I-SELECT 2 PLUG 325MA BL | 28001109 | CAD (712.6 KB) |
I-SELECT 2 PLUG 350MA BL | 28001110 | CAD (712.6 KB) |
I-SELECT 2 PLUG 375MA BL | 28001111 | CAD (712.6 KB) |
I-SELECT 2 PLUG 400MA BL | 28001112 | CAD (712.6 KB) |
I-SELECT 2 PLUG 425MA BL | 28001251 | CAD (712.6 KB) |
I-SELECT 2 PLUG 450MA BL | 28001113 | CAD (712.6 KB) |
I-SELECT 2 PLUG 475MA BL | 28001252 | CAD (712.6 KB) |
I-SELECT 2 PLUG 500MA BL | 28001114 | CAD (712.6 KB) |
I-SELECT 2 PLUG 525MA BL | 28001960 | CAD (712.6 KB) |
I-SELECT 2 PLUG 550MA BL | 28001115 | CAD (712.6 KB) |
I-SELECT 2 PLUG 600MA BL | 28001116 | CAD (712.6 KB) |
I-SELECT 2 PLUG 650MA BL | 28001117 | CAD (712.6 KB) |
I-SELECT 2 PLUG 700MA BL | 28001118 | CAD (712.6 KB) |
I-SELECT 2 PLUG 750MA BL | 28001119 | CAD (712.6 KB) |
I-SELECT 2 PLUG 800MA BL | 28001120 | CAD (712.6 KB) |
I-SELECT 2 PLUG 850MA BL | 28001121 | CAD (712.6 KB) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712.6 KB) |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
LCI 100/200-850/300 o4a sl PRE | 28002052 | CAD (514.0 KB) |
EPD | ||
---|---|---|
Type | Article number | Environmental Product Declaration (EPD) |
LCI 100/200-850/300 o4a sl PRE | 28002052 | EPD |