Driver LC 200W 48V one4all NF SC EXC
excite series 48 V – dimmable (IP20)
Product description
- NEW: lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
- Dimmable 48 V constant voltage LED driver for flexible constant voltage strips
- Can be either used built-in or independent with clip-on strain-relief
- The strain relief is included in both packaging variants. In the single packaging (SP) each Driver has also an individual
packaging
- one4all interface enables different dimming options
- Dimming range 1 to 100 %
- No additional external dimmer is needed
- Suitable for emergency escape lighting systems acc. to EN 50172
- Nominal lifetime up to 100,000 h
- 5 years guarantee
Typical applications
- Cove lighting, facade accent lighting, ceiling integration
Technical details
- 48 V, 200 W
- Small cross section
- Push terminals for simple wiring
Interfaces
- Near field communication (NFC)
- one4all (DALI-2, DSI, switchDIM, corridorFUNCTION)
- Terminal blocks: 45° push terminals
System solution
- Tridonic LLE FLEX 8 mm 48V EXC 600, 1,200, 1,800, 2,500 lm/m
- Tridonic LLE FLEX 12 mm 48V EXC 3,000, 4,000 lm/m
- Test the function of third party light sources before use at low dimming levels to ensure the dimming function works
perfectly
- Luminaire types:
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Rated supply voltage |
220 – 240 V |
AC voltage range |
198 – 264 V |
DC voltage range |
176 – 280 V |
Mains frequency |
0 / 50 / 60 Hz |
Typ. rated current (at 230 V, 50 Hz, full load)
(1) |
1,100 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) |
155 mA |
Leakage current (at 230 V, 50 Hz, full load)
(1) |
< 550 µA |
Max. input power |
215 W |
Output power range (P_rated) |
20 – 200 W |
Typ. efficiency (at 230 V, 50 Hz, full load) |
95 % |
λ (at 230 V, 50 Hz, full load)
(1) |
0.99 |
Typ. power consumption on stand-by |
< 0.2 W |
Typ. input current in no-load operation |
< 60 mA |
Typ. input power in no-load operation |
< 0.3 W |
In-rush current (peak / duration) |
89.3 A / 275 µs |
THD (at 230 V, 50 Hz, full load)
(1) |
< 6 % |
Starting time (at 230 V, 50 Hz, full load)
(1) |
< 0.6 s |
Starting time (DC mode) |
< 0.4 s |
Switchover time (AC/DC) |
< 0.2 s |
Turn off time (at 230 V, 50 Hz, full load) |
< 0.03 s |
Output voltage tolerance |
± 2 V |
Output LF voltage ripple (< 120 Hz) |
± 5 % |
Max. output voltage (U-OUT) |
60 V |
PWM frequency |
~ 1 kHz |
Dimming range |
1 – 100 % |
Mains surge capability (between L - N) |
1 kV |
Mains surge capability (between L/N - PE) |
2 kV |
Type of protection |
IP20 |
Lifetime |
up to 100,000 h |
Guarantee |
5 Year(s) |
Dimensions L x W x H |
325 x 43 x 30 mm |
Type |
Load |
Output voltage |
Output current |
Max. output power (at full load) |
Typ. power consumption (at full load) |
Typ. current consumption |
tc point max. |
Ambient temperature ta |
LC 200W 48V one4all NF SC EXC
|
10 % |
48 V |
417 mA |
20 W |
24.0 W |
139 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC
|
20 % |
48 V |
833 mA |
40 W |
44.1 W |
221 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC
|
30 % |
48 V |
1,250 mA |
60 W |
64.3 W |
300 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC
|
40 % |
48 V |
1,667 mA |
80 W |
84.8 W |
385 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC
|
50 % |
48 V |
2,083 mA |
100 W |
105.4 W |
473 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC
|
60 % |
48 V |
2,500 mA |
120 W |
126.1 W |
561 mA |
86 °C |
-25 ... +55 °C |
LC 200W 48V one4all NF SC EXC
|
70 % |
48 V |
2,917 mA |
140 W |
146.9 W |
651 mA |
86 °C |
-25 ... +55 °C |
LC 200W 48V one4all NF SC EXC
|
80 % |
48 V |
3,333 mA |
160 W |
167.8 W |
741 mA |
87 °C |
-25 ... +50 °C |
LC 200W 48V one4all NF SC EXC
|
90 % |
48 V |
3,750 mA |
180 W |
188.9 W |
833 mA |
90 °C |
-25 ... +45 °C |
LC 200W 48V one4all NF SC EXC
|
100 % |
48 V |
4,167 mA |
200 W |
210.2 W |
925 mA |
90 °C |
-25 ... +45 °C |
LC 200W 48V one4all NF SC EXC SP
|
10 % |
48 V |
417 mA |
20 W |
24.0 W |
139 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC SP
|
20 % |
48 V |
833 mA |
40 W |
44.1 W |
221 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC SP
|
30 % |
48 V |
1,250 mA |
60 W |
64.3 W |
300 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC SP
|
40 % |
48 V |
1,667 mA |
80 W |
84.8 W |
385 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC SP
|
50 % |
48 V |
2,083 mA |
100 W |
105.4 W |
473 mA |
84 °C |
-25 ... +60 °C |
LC 200W 48V one4all NF SC EXC SP
|
60 % |
48 V |
2,500 mA |
120 W |
126.1 W |
561 mA |
86 °C |
-25 ... +55 °C |
LC 200W 48V one4all NF SC EXC SP
|
70 % |
48 V |
2,917 mA |
140 W |
146.9 W |
651 mA |
86 °C |
-25 ... +55 °C |
LC 200W 48V one4all NF SC EXC SP
|
80 % |
48 V |
3,333 mA |
160 W |
167.8 W |
741 mA |
87 °C |
-25 ... +50 °C |
LC 200W 48V one4all NF SC EXC SP
|
90 % |
48 V |
3,750 mA |
180 W |
188.9 W |
833 mA |
90 °C |
-25 ... +45 °C |
LC 200W 48V one4all NF SC EXC SP
|
100 % |
48 V |
4,167 mA |
200 W |
210.2 W |
925 mA |
90 °C |
-25 ... +45 °C |
Type |
Article number |
CAD Files |
LC 200W 48V one4all NF SC EXC
|
28003536
|
CAD
(667.7 KB)
|
LC 200W 48V one4all NF SC EXC SP
|
28003843
|
CAD
(667.7 KB)
|