- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Linear dimming non-SELV
- ►
- 16 mm premium NFC
- ►
- LC 40 W 75–400 mA bDW NFC h16 PRE4
Driver LC 40W 75–400mA 230V bDW NFC h16 PRE4 NEW
16 mm premium NFC series
Product description
- NEW: lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
- Dimmable built-in constant current LED driver
- Dimming range 1 to 100 %
- For luminaires of protection class I and protection class II
- Adjustable output current between 75 and 400 mA
- Max. output power 40 W
- Up to 92.2 % efficiency
- Power input on stand-by < 0.14 W
- Nominal lifetime up to 100,000 h
- 5 years guarantee
Housing properties
- Low profile metal casing with white cover
- Only 16 mm housing height
- Type of protection IP20
Interfaces
- basicDIM Wireless
- Near field communication (NFC)
- switchDIM
- Terminal blocks: 0° push terminals
Functions
- Adjustable output current in 1-mA-steps (NFC)
- lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
- Constant light output function (eCLO)
- Power-up fading at AC
- Switch off the driver with fade2zero
- Protective features (overtemperature, short-circuit, overload, no-load)
- Suitable for emergency escape lighting systems acc. to EN 50172
Benefits
- Flexible configuration via companionSUITE
- Support NFC multiple programming (full carton box)
- Application-oriented operating window for maximum compatibility
- Best energy savings due to low stand-by losses and high efficiency
- Reliability proven by lifetime up to 100,000 h and 5 years guarantee
Typical applications
- For linear/area lighting in office applications
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LC 40/75-400/230 bDW NF h16 PRE4 | 28004618 | 10 pc(s). | 920 pc(s). | 0.155 kg |
- Luminaire types:
-
-
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. rated current (at 230 V, 50 Hz, full load) (1) (2) | 194 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 40 mA |
Leakage current (PE) | < 250 µA |
Max. input power | 44 W |
Output power range (P_rated) | 3.38 – 40 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 92.2 % |
λ over full operating range (max.) (1) | 0.99 |
λ over full operating range (min.) | 0.43C |
Typ. power consumption on stand-by | < 0.14 W |
Typ. input current in no-load operation | 24.6 mA |
Typ. input power in no-load operation | 0.33 W |
In-rush current (peak / duration) | 24.1 A / 181 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 5 % |
Starting time (AC mode) | < 0.7 s |
Starting time (DC mode) | < 0.35 s |
Switchover time (AC/DC) (3) | < 0.3 s |
Turn off time (at 230 V, 50 Hz, full load) | < 50 ms |
Output current tolerance (1) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 40 % |
Output LF current ripple (< 120 Hz) | ± 1.5 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 250 V |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Surge voltage at output side (against PE) | < 2 kV |
Type of protection | IP20 |
Radio transceiver operating frequencies | 2.4 – 2.483 GHz |
Max. output power radio transceiver (E.R.I.P.) (4) | < + 20 dBm |
Lifetime | up to 100,000 h |
Guarantee | 5 Year(s) |
Dimensions L x W x H | 280 x 30 x 16 mm |
Specific technical data | ||||||||
---|---|---|---|---|---|---|---|---|
Type | Output current (1) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | Ambient temperature ta |
LC 40/75-400/230 bDW NF h16 PRE4 | 75 mA | 45 V | 230.0 V | 17.3 W | 19.5 W | 93 mA | 78 °C | -20 ... +70 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 100 mA | 45 V | 230.0 V | 23.0 W | 25.5 W | 117 mA | 79 °C | -20 ... +70 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 150 mA | 45 V | 230.0 V | 34.5 W | 37.4 W | 165 mA | 77 °C | -20 ... +70 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 200 mA | 45 V | 200.0 V | 40.0 W | 43.2 W | 191 mA | 77 °C | -20 ... +65 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 250 mA | 45 V | 160.0 V | 40.0 W | 43.4 W | 191 mA | 80 °C | -20 ... +65 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 300 mA | 45 V | 133.3 V | 40.0 W | 43.5 W | 192 mA | 80 °C | -20 ... +65 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 350 mA | 45 V | 114.3 V | 40.0 W | 43.8 W | 193 mA | 78 °C | -20 ... +60 °C |
LC 40/75-400/230 bDW NF h16 PRE4 | 400 mA | 45 V | 100.0 V | 40.0 W | 44.0 W | 194 mA | 78 °C | -20 ... +60 °C |
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |