- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- premium 24 V – dimmable (IP20)
- LC 35 W 24 V bDW SC PRE2
- LC 60 W 24 V bDW SC PRE2
- LC 100 W 24 V bDW SC PRE2
- LC 150 W 24 V bDW SC PRE2
- LC 18 W 24 V one4all SC PRE
- LCA 35 W 24 V one4all SC PRE
- LCA 60 W 24 V one4all SC PRE
- LCA 100 W 24 V one4all SC PRE
- LCA 150 W 24 V one4all SC PRE
- LC 18 W 24 V one4all lp PRE
- LC 35 W 24 V one4all lp PRE
- LC 60 W 24 V one4all lp PRE
- LCA 100 W 24 V one4all lp PRE
- excite 48 V – dimmable (IP20)
- excite 24 V – non-dimmable (IP67)
- excite 12 V – non-dimmable (IP20)
- essence 24 V – non-dimmable (IP20)
- premium 24 V – dimmable (IP20)
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Constant voltage
- ►
- premium 24 V – dimmable (IP20)
- ►
- LC 60 W 24 V bDW SC PRE2
Driver LC 60W 24V bDW SC PRE2
premium series 24 V – dimmable (IP20)
Product description
- NEW: lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
- Dimmable 24 V constant voltage LED driver for flexible constant voltage strips
- Can bei either used built-in or independent with clip-on strain-relief (see data sheet chapter: 1. Standards)
- The strain relief is included in both packaging variants. In the single packaging (SP) each Driver has also an individual packaging
- basicDIM Wireless enables different dimming options
- Forms automatically a wireless communication network with up to 250 nodes
- Dimming range 1 to 100 %
- No additional external dimmer is needed
- Suitable for emergency escape lighting systems acc. to EN 50172
- Nominal lifetime up to 50,000 h
- 5 years guarantee
Typical applications
- Cove lighting, facade accent lighting, ceiling integration
Technical details
- 24 V, 60 W
- Small design (225 x 43 x 30.2 mm) with stretched-compact strain relief
- Small cross section
- Push terminals for simple wiring
- Output terminals (+/–) equipped twice for more flexibility in the application
Interfaces
- basicDIM Wireless
- ready2mains (configuration via mains)
- Terminal blocks: 45° push terminals
System solution
- Tridonic LLE-FLEX ADV 600, 1,200, 1,800 lm/m
- Tridonic LLE-FLEX EXC 600, 1,200, 1,800, 2,500 lm/m
- In connection with Flex accessories wire to PCB plug
- Test the function of third party light sources before use at low dimming levels to ensure the dimming function works perfectly
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
Multi packaging | ||||
LC 60/24V bDW SC PRE2 | 28002416 | 10 pc(s). | 390 pc(s). | 0.176 kg |
Single packaging | ||||
LC 60/24V bDW SC PRE2 SP | 28002674 | 10 pc(s). | 480 pc(s). | 0.176 kg |
- Luminaire types:
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. rated current (at 230 V, 50 Hz, full load) (1) | 295 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) | 59 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) | < 320 µA |
Max. input power | 67 W |
Typ. efficiency (at 230 V, 50 Hz, full load) | 93 % |
λ (at 230 V, 50 Hz, full load) (1) | 0.98 |
Typ. power consumption on stand-by | < 0.35 W |
Typ. input current in no-load operation | 35.8 mA |
Typ. input power in no-load operation | 2.05 W |
In-rush current (peak / duration) | 32.2 A / 187 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 5.3 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Starting time (DC mode) | < 0.3 s |
Switchover time (AC/DC) (2) | < 0.3 s |
Turn off time (at 230 V, 50 Hz, full load) | < 3 ms |
Output voltage tolerance | ± 1 V |
Output LF voltage ripple (< 120 Hz) | ± 5 % |
Max. output voltage (U-OUT) | 60 V |
PWM frequency | ~ 1 kHz |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Type of protection | IP20 |
Radio transceiver operating frequencies | 2.4 – 2.483 GHz |
Max. output power radio transceiver (E.R.I.P.) (3) | < + 20 dBm |
Lifetime | up to 50,000 h |
Guarantee | 5 Year(s) |
Dimensions L x W x H | 225 x 43 x 30.2 mm |
Specific technical data | ||||||||
---|---|---|---|---|---|---|---|---|
Type | Load | Output voltage | Output current | Max. output power (at full load) | Typ. power consumption (at full load) | Typ. current consumption | tc point max. | Ambient temperature ta |
LC 60/24V bDW SC PRE2 | 10 % | 24 V | 250 mA | 6 W | 8.9 W | 61 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 | 20 % | 24 V | 500 mA | 12 W | 15.3 W | 88 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 | 30 % | 24 V | 750 mA | 18 W | 21.4 W | 106 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 | 40 % | 24 V | 1,000 mA | 24 W | 27.8 W | 132 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 | 50 % | 24 V | 1,250 mA | 30 W | 34.1 W | 157 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 | 60 % | 24 V | 1,500 mA | 36 W | 40.6 W | 184 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 | 70 % | 24 V | 1,750 mA | 42 W | 47.0 W | 212 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 | 80 % | 24 V | 2,000 mA | 48 W | 53.5 W | 239 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 | 90 % | 24 V | 2,250 mA | 54 W | 60.0 W | 267 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 | 100 % | 24 V | 2,500 mA | 60 W | 66.4 W | 295 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 SP | 10 % | 24 V | 250 mA | 6 W | 8.9 W | 61 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 SP | 20 % | 24 V | 500 mA | 12 W | 15.3 W | 88 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 SP | 30 % | 24 V | 750 mA | 18 W | 21.4 W | 106 mA | 75 °C | -25 ... +60 °C |
LC 60/24V bDW SC PRE2 SP | 40 % | 24 V | 1,000 mA | 24 W | 27.8 W | 132 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 SP | 50 % | 24 V | 1,250 mA | 30 W | 34.1 W | 157 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 SP | 60 % | 24 V | 1,500 mA | 36 W | 40.6 W | 184 mA | 75 °C | -25 ... +55 °C |
LC 60/24V bDW SC PRE2 SP | 70 % | 24 V | 1,750 mA | 42 W | 47.0 W | 212 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 SP | 80 % | 24 V | 2,000 mA | 48 W | 53.5 W | 239 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 SP | 90 % | 24 V | 2,250 mA | 54 W | 60.0 W | 267 mA | 75 °C | -25 ... +50 °C |
LC 60/24V bDW SC PRE2 SP | 100 % | 24 V | 2,500 mA | 60 W | 66.4 W | 295 mA | 75 °C | -25 ... +50 °C |
Further information
- FAQ – LED systems (http://www.ready2mains.eu/com/en/faq-led.asp)
- Reference projects (http://www.ready2mains.eu/com/en/reference-projects.asp)
- Environmental declarations (http://www.ready2mains.eu/com/en/environmental-declarations.asp)
- Tender text (http://www.ready2mains.eu/com/en/tender.asp)
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |
EPD | ||
---|---|---|
Type | Article number | Environmental Product Declaration (EPD) |
LC 60/24V bDW SC PRE2 | 28002416 | EPD |