Driver LC 60W 24V MTR SC PRE2 NEW

premium series 24 V – dimmable (IP20)

  • With strain-relief

    With strain-relief

Product description

  • Available soon
  • Matter certified device
  • Communication via an IPv6 Thread Network
  • Thread Border Router is required (e.g. Apple HomePod mini or Google NestHub)
  • Independent push-button input for free configuration
  • Wireless firmware updates possible
  • Dimmable 24 V constant voltage LED driver for flexible constant voltage strips
  • Can bei either used built-in or independent with clip-on strain-relief (see data sheet chapter: 1. Standards)
  • Dimming range 1 to 100 %
  • No additional external dimmer is needed
  • Suitable for emergency escape lighting systems acc. to EN 50172
  • Nominal lifetime up to 50,000 h
  • 5 years guarantee

Typical applications

  • Cove lighting, facade accent lighting, ceiling integration

Technical details

  • 24 V, 60 W
  • Small design (225 x 43 x 30.2 mm) with stretched-compact strain relief
  • Small cross section
  • Push terminals for simple wiring
  • Output terminals (+/–) equipped twice for more flexibility in the application

Interfaces

  • Matter
  • Terminal blocks: 45° push terminals

System solution

  • Tridonic LLE-FLEX ADV 600, 1,200, 1,800 lm/m
  • Tridonic LLE-FLEX EXC 600, 1,200, 1,800, 2,500 lm/m
  • In connection with Flex accessories wire to PCB plug
  • Test the function of third party light sources before use at low dimming levels to ensure the dimming function works perfectly
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton (1) Pack­ag­ing, pallet
Multi packaging
LC 60/24V MTR SC PRE2 28004486 1 pc(s). 1 pc(s).
Single packaging
LC 60/24V MTR SC PRE2 SP 28004490 1 pc(s). 1 pc(s).
Luminaire types:
Decorative luminaires
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Typ. rated current (at 230 V, 50 Hz, full load) (1) 295 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) 59 mA
Leakage current (at 230 V, 50 Hz, full load) (1) < 320 µA
Max. input power 67 W
Output power range (P_rated) 6 – 60 W
Typ. efficiency (at 230 V, 50 Hz, full load) 93 %
λ over full operating range (max.) (1) 0.98
λ over full operating range (min.) 0.54C
Typ. power consumption on stand-by < 0.35 W
Typ. input current in no-load operation 35.8 mA
Typ. input power in no-load operation 2.05 W
In-rush current (peak / duration) 32.2 A / 187 µs
THD (at 230 V, 50 Hz, full load) (1) < 5.3 %
Starting time (at 230 V, 50 Hz, full load) (1) < 0.6 s
Starting time (DC mode) < 0.3 s
Switchover time (AC/DC) (2) < 0.3 s
Turn off time (at 230 V, 50 Hz, full load) < 3 ms
Output voltage tolerance ± 1 V
Output LF voltage ripple (< 120 Hz) ± 5 %
Max. output voltage (U-OUT) 60 V
PWM frequency ~ 1 kHz
Dimming range 1 – 100 %
Mains surge capability (between L - N) 1 kV
Mains surge capability (between L/N - PE) 2 kV
Type of protection IP20
Radio transceiver operating frequencies 2.4 – 2.483 GHz
Max. output power radio transceiver (E.R.I.P.) (3) < + 20 dBm
Lifetime up to 50,000 h
Guarantee 5 Year(s)
Dimensions L x W x H 225 x 43 x 30.2 mm
Autoscroll for tables
Specific technical data
Type Load Output voltage Output current Max. output power (at full load) Typ. power con­sump­tion (at full load) Typ. current consumption tc point max. Ambient temperature ta
LC 60/24V MTR SC PRE2 10 % 24 V 250 mA 6 W 8.9 W 61 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 20 % 24 V 500 mA 12 W 15.3 W 88 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 30 % 24 V 750 mA 18 W 21.4 W 106 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 40 % 24 V 1,000 mA 24 W 27.8 W 132 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 50 % 24 V 1,250 mA 30 W 34.1 W 157 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 60 % 24 V 1,500 mA 36 W 40.6 W 184 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 70 % 24 V 1,750 mA 42 W 47.0 W 212 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 80 % 24 V 2,000 mA 48 W 53.5 W 239 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 90 % 24 V 2,250 mA 54 W 60.0 W 267 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 100 % 24 V 2,500 mA 60 W 66.4 W 295 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 SP 10 % 24 V 250 mA 6 W 8.9 W 61 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 SP 20 % 24 V 500 mA 12 W 15.3 W 88 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 SP 30 % 24 V 750 mA 18 W 21.4 W 106 mA 75 °C -25 ... +60 °C
LC 60/24V MTR SC PRE2 SP 40 % 24 V 1,000 mA 24 W 27.8 W 132 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 SP 50 % 24 V 1,250 mA 30 W 34.1 W 157 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 SP 60 % 24 V 1,500 mA 36 W 40.6 W 184 mA 75 °C -25 ... +55 °C
LC 60/24V MTR SC PRE2 SP 70 % 24 V 1,750 mA 42 W 47.0 W 212 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 SP 80 % 24 V 2,000 mA 48 W 53.5 W 239 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 SP 90 % 24 V 2,250 mA 54 W 60.0 W 267 mA 75 °C -25 ... +50 °C
LC 60/24V MTR SC PRE2 SP 100 % 24 V 2,500 mA 60 W 66.4 W 295 mA 75 °C -25 ... +50 °C
Document Size Date  
 
Driver_LC_60W_24V_MTR_SC_PRE2_en.pdf
Data sheet
1.77 MB 06/12/2023
Matter_Commissioning_Quick_Guide.pdf
Matter – Commissioning Quick Guide
1.21 MB 01/06/2023
Without strain-relief
Without strain-relief
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
 
 
Visiting from the US or Canada?
Go to our dedicated site.
http://www.tridonic.us or stay on tridonic.com