Driver LCO 40W 200–1050mA 64V NFC C ADV3

advanced NFC outdoor series

Product description

  • Dimmable built-in constant current LED driver
  • Dimming range 5 – 100 % (min. 10 mA)
  • For luminaires of protection class I and protection class II
  • Temperature protection as per EN 61347-2-13 C5e
  • Output current adjustable between 200 – 1,050 mA via NFC or ready2mains Programmer
  • Max. output power 40 W
  • Up to 91 % efficiency
  • Lowest power input on stand-by < 0.16 W
  • Nominal lifetime of 100,000 h and 8 years guarantee

Interfaces

  • Near field communication (NFC)
  • ready2mains (configuration via mains)
  • U6Me2 (configuration of chronoSTEP via mains)
  • Terminal blocks: 45° push terminals

Functions

  • Adjustable output current in 1-mA-steps (NFC, ready2mains)
  • Programmable chronoSTEP: times and levels (NFC, U6Me2, ready2mains)
  • Dimming through mains voltage (inputDIM)
  • Enhanced constant light output function (eCLO)
  • Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
  • Intelligent Temperature Guard (ITG)
  • Intelligent Voltage Guard Plus (IVG+)
  • Suitable for emergency escape lighting systems acc. to EN 50172

Benefits

  • Flexible configuration via companionSUITE (NFC, ready2mains™) or U6Me2 programmer
  • Application-oriented operating window for maximum compatibility
  • Best energy savings due to low stand-by losses and high efficiency
  • In-field programming possible after installation with NFC interface and ready2mains
  • High overvoltage protection: up to 10 kV asymmetric (protection class I and II)

Typical applications

  • Road, street and industry
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, pallet Weight per pc.
LCO 40/200-1050/64 NF C ADV3 87500823 20 pc(s). 240 pc(s). 0.204 kg
Luminaire types:
Street lanterns
Approval marks:
Zhaga NFC
NFC
IP20
SELV
130
Short Circuit Proof
doppelte Isolierung
r2m
Emergency Lighting suitable
EAC
CCC
RCM
CE
UKCA
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
inputDIM voltage range 170 – 250V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. current (at 230 V, 50 Hz, full load) (1) (2) 56 – 200 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 10 – 35 mA
Leakage current (at 230 V, 50 Hz, full load) (1) (2) < 325 µA
Touch current (equipotential connected) (3) 430 µA
Max. input power 46 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) (4) 91 %
λ (at 230 V, 50 Hz, full load) (1) 0.97
Typ. power consumption on stand-by (5) < 0.16 W
In-rush current (peak / duration) 24.88 A / 236 µs
THD (at 230 V, 50 Hz, full load) (1) < 8 %
Starting time (AC mode) < 500 ms
Starting time (DC mode) < 500 ms
Switchover time (AC/DC) (6) < 300 ms
Turn off time (at 230 V, 50 Hz, full load) < 500 ms
Output current tolerance (1) (7) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 15 %
Output LF current ripple (< 120 Hz) ± 3.3 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 90 V
Max. output voltage (HV) 90 V
Max. output voltage (LV) 50 V
Dimming range 5 – 100 % (min. 10 mA)
Mains surge capability (between L - N) (8) 6 kV / 3 kA
Mains surge capability (between L/N - PE) (9) 10 kV
Burst protection 6 kV
Surge voltage at output side (against PE) < 1 kV
Type of protection IP20
Lifetime up to 100,000 h
Guarantee 8 Year(s)
Dimensions L x W x H 123 x 77 x 31 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Min. output voltage Max. output voltage Max. output power Typ. power con­sump­tion (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) tc point max. Ambient temperature ta
High voltage output (HV)
LCO 40/200-1050/64 NF C ADV3 200 mA 32.0 V 64.0 V 12.8 W 15.8 W 76 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 250 mA 30.0 V 64.0 V 16.0 W 19.1 W 88 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 300 mA 30.0 V 64.0 V 19.2 W 22.4 W 101 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 350 mA 30.0 V 64.0 V 22.4 W 25.7 W 116 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 400 mA 30.0 V 64.0 V 25.6 W 30.5 W 130 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 450 mA 30.0 V 64.0 V 28.8 W 32.5 W 148 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 500 mA 30.0 V 64.0 V 32.0 W 35.9 W 160 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 550 mA 30.0 V 64.0 V 35.2 W 39.5 W 174 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 600 mA 30.0 V 64.0 V 38.4 W 42.8 W 191 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 650 mA 30.0 V 61.5 V 40.0 W 44.3 W 195 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 700 mA 30.0 V 57.1 V 40.0 W 44.2 W 196 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 750 mA 30.0 V 53.3 V 40.0 W 44.0 W 195 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 800 mA 30.0 V 50.0 V 40.0 W 44.0 W 195 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 850 mA 30.0 V 47.1 V 40.0 W 44.1 W 195 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 900 mA 30.0 V 44.4 V 40.0 W 44.0 W 195 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 950 mA 30.0 V 42.1 V 40.0 W 44.2 W 195 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 1,000 mA 18.0 V 38.0 V 38.0 W 42.9 W 190 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 1,050 mA 18.0 V 38.0 V 39.9 W 45.0 W 200 mA 85 °C -40 ... +65 °C
Low voltage output (LV)
LCO 40/200-1050/64 NF C ADV3 200 mA 32.0 V 38.0 V 7.6 W 10.7 W 56 mA 80 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 250 mA 25.6 V 38.0 V 9.5 W 12.8 W 64 mA 80 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 300 mA 21.3 V 38.0 V 11.4 W 14.7 W 71 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 350 mA 18.3 V 38.0 V 13.3 W 16.8 W 79 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 400 mA 18.0 V 38.0 V 15.2 W 18.7 W 87 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 450 mA 18.0 V 38.0 V 17.1 W 21.0 W 95 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 500 mA 18.0 V 38.0 V 19.0 W 22.7 W 104 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 550 mA 18.0 V 38.0 V 20.9 W 24.8 W 112 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 600 mA 18.0 V 38.0 V 22.8 W 26.8 W 121 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 650 mA 18.0 V 38.0 V 24.7 W 29.0 W 130 mA 85 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 700 mA 18.0 V 38.0 V 26.6 W 31.0 W 138 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 750 mA 18.0 V 38.0 V 28.5 W 33.0 W 147 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 800 mA 18.0 V 38.0 V 30.4 W 34.8 W 155 mA 90 °C -40 ... +70 °C
LCO 40/200-1050/64 NF C ADV3 850 mA 18.0 V 38.0 V 32.3 W 37.0 W 163 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 900 mA 18.0 V 38.0 V 34.2 W 39.0 W 173 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 950 mA 18.0 V 38.0 V 36.1 W 41.0 W 181 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 1,000 mA 18.0 V 38.0 V 38.0 W 42.9 W 190 mA 85 °C -40 ... +65 °C
LCO 40/200-1050/64 NF C ADV3 1,050 mA 18.0 V 38.0 V 39.9 W 45.0 W 200 mA 85 °C -40 ... +65 °C
Document      Size       Date       
 
Driver_LCO_40W_200-1050mA_64V_NF_C_ADV3_en.pdf
Data sheet
2.37 MB 05/02/2024
Function_overview_LED_drivers_en.pdf
LED drivers – Functional description
3.35 MB 18/01/2024
NFC_readers_companionSUITE.pdf
NFC readers/writers supported by companionSUITE
5.95 MB 14/02/2023
Outdoor_smart_booklet_2022_EN.pdf
Smart booklet – Outdoor
7.73 MB 04/07/2023
Leaflet_companionSUITE_EN.pdf
Leaflet companionSUITE
2.26 MB 23/03/2022
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCO 40/200-1050/64 NF C ADV3 87500823 CAD (6.5 MB)
EPD
Type Article number Environmental Product Declaration (EPD)
LCO 40/200-1050/64 NF C ADV3 87500823 EPD
 
 
Visiting from the US or Canada?
Go to our dedicated site.
http://www.tridonic.us or stay on tridonic.com