Product description

  • Fixed output built-in LED driver
  • Constant current LED driver
  • Output current 1,750, 2,100 or 2,450 mA
  • Max. output power 150 W
  • Nominal lifetime up to 50,000 h
  • For luminaires of protection class I and protection class II
  • Temperature protection as per EN 61347-2-13 C5e
  • Article LCI 150W 2100mA TEC C (87500271) has the KC approval mark.
  • 5 years guarantee

Housing properties

  • Casing: polycarbonate, white
  • Brush-coated for higher protection against humidity
  • Type of protection IP20

Functions

  • Overtemperature protection
  • Overload protection
  • Short-circuit protection
  • No-load protection
  • Burst protection voltage up to 2 kV
  • Surge protection voltage up to 2 kV (L to N)
  • Surge protection voltage up to 4 kV (L/N to earth)
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, low volume Pack­ag­ing, high volume Weight per pc.
LCI 150W 1750mA TEC C 87500270 10 pc(s). 240 pc(s). 1,200 pc(s). 0.329 kg
LCI 150W 2100mA TEC C 87500271 10 pc(s). 240 pc(s). 1,200 pc(s). 0.328 kg
LCI 150W 2450mA TEC C 87500272 10 pc(s). 240 pc(s). 1,200 pc(s). 0.328 kg
Luminaire types:
Recessed floor & wallmounted luminaires
Free-standing luminaires
High bay luminaires
Linear luminaires
Spotlights
Wide-area luminaires (in-built, remote, pendant)
Approval marks:
IP20
SELV
130
Short Circuit Proof
doppelte Isolierung
EAC
CCC
RCM
CE
UKCA
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
Rated current (at 230 V, 50 Hz) 0.7 A
Mains frequency 50 / 60 Hz
Overvoltage protection 300 V AC, 1 h
Max. input power 170 W
Output power range 75 – 150 W
THD (at 230 V, 50 Hz, full load) < 10 %
THD (at 230 V, 50 Hz, min. load) < 20 %
Output current tolerance (1) ± 7.5 %
Typ. current ripple (at 230 V, 50 Hz, full load) < 3 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Starting time (at 230 V, 50 Hz, full load) ≤ 0.5 s
Turn off time (at 230 V, 50 Hz, full load) ≤ 0.5 s
Hold on time at power failure (output) 0 s
Ambient temperature ta -25 ... +60 °C
Ambient temperature ta (at lifetime 50,000 h) 60 °C
Max. casing temperature tc 95 °C
Storage temperature ts -40 ... +80 °C
Lifetime up to 50,000 h
Guarantee 5 Year(s)
Dimensions L x W x H 140 x 100 x 30 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Typ. power con­sump­tion (at 230 V, 50 Hz, full load) λ at full load Ef­fi­cien­cy at full load (2) λ over full operating range (min.) Ef­fi­cien­cy at min. load (2) Min. forward voltage Max. for­ward volt­age Max. output voltage (U-OUT) (2) Max. peak output current (2)
LCI 150W 1750mA TEC C 1,750 mA 158.5 W 0.98 94.5 % 0.93C 91.0 % 43.0 V 86.0 V 90 V 2,625 mA
LCI 150W 2100mA TEC C 2,100 mA 158.5 W 0.99 94.0 % 0.95 91.0 % 35.5 V 71.5 V 76 V 3,150 mA
LCI 150W 2450mA TEC C 2,450 mA 160.0 W 0.99 93.5 % 0.94C 89.5 % 30.5 V 61.0 V 65 V 3,675 mA
Document      Size       Date       
 
TALEXXconverter_LCI_150W_TEC_C_en.pdf
Data sheet
1.13 MB 21/06/2022
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCI 150W 1750mA TEC C 87500270 CAD (931.2 KB)
LCI 150W 2100mA TEC C 87500271 CAD (931.2 KB)
LCI 150W 2450mA TEC C 87500272 CAD (931.2 KB)