- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- premium series
- LC 10 W 150–400 mA bDW SC PRE2
- LC 17 W 250–700 mA bDW SC PRE2
- LC 25 W 350–1050 mA bDW SC PRE2
- LC 45 W 500–1400 mA bDW SC PRE2
- LCA 10 W 150–400 mA one4all C PRE
- LCA 17 W 250–700 mA one4all C PRE
- LCA 25 W 350–1050 mA one4all C PRE
- LCA 45 W 500–1400 mA one4all C PRE
- LCA 60 W 900–1750 mA one4all C PRE
- LCA 100 W 1100–2100 mA one4all C PRE
- LCA 10 W 150–400 mA one4all SC PRE
- LCA 17 W 250–700 mA one4all SC PRE
- LCA 25 W 350–1050 mA one4all SC PRE
- LCA 45 W 500–1400 mA one4all SC PRE
- LCA 10 W 150–400 mA one4all SR PRE
- LCA 17 W 250–700 mA one4all SR PRE
- LCA 25 W 350–1050 mA one4all SR PRE
- LCA 45 W 500–1400 mA one4all SR PRE
- LCA 60 W 900–1750 mA one4all SR PRE
- LCA 100 W 1100–2100 mA one4all SR PRE
- LCA 38 W 350–1050 mA 2xCH C PRE
- LCA 38 W 350–1050 mA 2xCH SR PRE
- excite series
- advanced series
- essence series
- Tunable White – compact
- premium series
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Compact dimming
- ►
- premium series
- ►
- LCA 25 W 350–1050 mA one4all SC PRE
Driver LCA 25W 350–1050mA one4all SC PRE
premium series
Product description
- NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
- Dimmable built-in constant current LED driver
- Can be either used built-in or independent with clip-on strain-relief (see accessory)
- Dimming range 1 to 100 %
- For luminaires of protection class I and protection class II
- Output current adjustable between 350 – 1,050 mA via ready2mains Programmer, I-SELECT 2 plugs or DALI
- Max. output power 25 W
- Up to 90 % efficiency
- Power input on stand-by < 0.15 W
- Nominal lifetime up to 100,000 h
- 5 years guarantee
Housing properties
- Casing: polycarbonate, white
- Type of protection IP20
Interfaces
- one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
- ready2mains (configuration and dimming via mains)
- Terminal blocks: 45° push terminals
Functions
- Adjustable output current in 1-mA-steps (DALI, ready2mains, I-SELECT 2)
- Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
- Constant light output function (CLO)
- Power-up fading at AC
- Configurable via ready2mains
- Switch off the driver with fade2zero
- Service monitor to log certain events
- Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
- Suitable for emergency escape lighting systems acc. to EN 50172
Benefits
- Application-oriented operating window for maximum compatibility
- Best energy savings due to low stand-by losses and high efficiency
- Flexible configuration via DALI, ready2mains and I-SELECT 2
Typical applications
- For linear/area lighting in office applications
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LCA 25W 350-1050mA one4all SC PRE | 28000675 | 10 pc(s). | 1,000 pc(s). | 0.127 kg |
- Luminaire types:
-
-
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. current (at 230 V, 50 Hz, full load) (1) (2) | 95.4 – 127.6 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 22.8 – 28.4 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 350 µA |
Max. input power | 28.7 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 90 % |
λ (at 230 V, 50 Hz, full load) | 0.96 |
Typ. power consumption on stand-by (3) | < 0.15 W |
Typ. input current in no-load operation | 17.3 mA |
Typ. input power in no-load operation | 0.53 W |
In-rush current (peak / duration) | 26 A / 151 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 8 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Starting time (DC mode) | < 0.33 s |
Switchover time (AC/DC) (4) | < 0.33 s |
Turn off time (at 230 V, 50 Hz, full load) | < 20 ms |
Output current tolerance (1) (5) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 40 % |
Output LF current ripple (< 120 Hz) | ± 2.5 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 60 V |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Surge voltage at output side (against PE) | < 0.5 kV |
Type of protection | IP20 |
Lifetime | up to 100,000 h |
Guarantee | 5 Year(s) |
Dimensions L x W x H | 130 x 43 x 30 mm |
Specific technical data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Type | Output current (1) (2) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | Ambient temperature ta | I-SELECT 2 resistor value (3) |
LCA 25W 350-1050mA one4all SC PRE | 350 mA | 20 V | 50 V | 17.5 W | 20.9 W | 94 mA | 75 °C | -25 ... +55 °C | – |
LCA 25W 350-1050mA one4all SC PRE | 400 mA | 20 V | 50 V | 20.0 W | 23.5 W | 106 mA | 75 °C | -25 ... +55 °C | 12.50 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 450 mA | 20 V | 50 V | 22.5 W | 26.1 W | 116 mA | 75 °C | -25 ... +55 °C | 11.11 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 500 mA | 20 V | 50 V | 25.0 W | 28.7 W | 128 mA | 75 °C | -25 ... +55 °C | 10.00 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 550 mA | 20 V | 45 V | 24.8 W | 28.4 W | 126 mA | 75 °C | -25 ... +55 °C | 9.09 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 600 mA | 20 V | 41 V | 24.6 W | 28.3 W | 126 mA | 75 °C | -25 ... +55 °C | 8.33 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 650 mA | 20 V | 38 V | 24.7 W | 28.2 W | 125 mA | 75 °C | -25 ... +60 °C | 7.69 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 700 mA | 20 V | 35 V | 24.5 W | 28.1 W | 125 mA | 75 °C | -25 ... +60 °C | 7.14 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 750 mA | 20 V | 33 V | 24.8 W | 28.1 W | 125 mA | 75 °C | -25 ... +60 °C | 6.67 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 800 mA | 20 V | 31 V | 24.8 W | 28.2 W | 125 mA | 75 °C | -25 ... +60 °C | 6.25 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 850 mA | 20 V | 29 V | 24.7 W | 28.2 W | 125 mA | 75 °C | -25 ... +60 °C | 5.88 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 900 mA | 20 V | 27 V | 24.3 W | 28.3 W | 126 mA | 75 °C | -25 ... +55 °C | 5.56 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 950 mA | 20 V | 26 V | 24.7 W | 28.4 W | 125 mA | 75 °C | -25 ... +55 °C | 5.26 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 1,000 mA | 20 V | 25 V | 25.0 W | 28.4 W | 126 mA | 75 °C | -25 ... +55 °C | 5.00 kΩ |
LCA 25W 350-1050mA one4all SC PRE | 1,050 mA | 20 V | 23 V | 24.2 W | 28.6 W | 126 mA | 75 °C | -25 ... +55 °C | 0.00 kΩ |
Further information
- ready2mains™ (http://www.ready2mains.eu/com/en/products/luxcontrol-ready2mains.asp)
- FAQ – LED systems (http://www.ready2mains.eu/com/en/faq-led.asp)
- Reference projects (http://www.ready2mains.eu/com/en/reference-projects.asp)
- Environmental declarations (http://www.ready2mains.eu/com/en/environmental-declarations.asp)
- Tender text (http://www.ready2mains.eu/com/en/tender.asp)
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |
Strain-relief set 43x30mm Accessories
- Approval marks:
-
-
-
Product description
- Optional strain-relief set for independent applications
- Transforms the LED driver into a fully class II compatible LED driver (e.g. ceiling installation)
- Easy and tool-free mounting to the LED driver, screwless cable-clamp channels for long strain-relief (30 x 43 x 30 mm)
- With screws for short strain-relief (15 x 34 x 30 mm)
- Overall length = length L (LED driver) + 2 x 30 mm (long strain-relief set), 2 x 15 mm ( short strain-relief) or long and short strain-relief any combination
- Standard SC (L = 30 mm) available as non-pre-assembled and pre-assembled
- Short SC (L = 15 mm) only pre-assembled available
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton (1) | Packaging, outer box | Weight per pc. |
ACU SC 43x30mm CLIP-ON SR SET | 28001168 | 10 pc(s). | 500 pc(s). | 0.038 kg |
ACU SC 43x30mm CLIP-ON SR SET 300 | 28001351 | 300 pc(s). | 300 pc(s). | 0.038 kg |
ACU SC 30x43x30mm CLIP-ON SR PA | 28001699 | 10 pc(s). | 500 pc(s). | 0.021 kg |
ACU SC 15x43x30mm CLIP-ON SR PA | 28001574 | 10 pc(s). | 1,200 pc(s). | 0.010 kg |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
ACU SC 43x30mm CLIP-ON SR SET | 28001168 | CAD (3.7 MB) |
ACU SC 43x30mm CLIP-ON SR SET 300 | 28001351 | CAD (3.7 MB) |
ACU SC 30x43x30mm CLIP-ON SR PA | 28001699 | CAD (3.7 MB) |
ACU SC 15x43x30mm CLIP-ON SR PA | 28001574 | CAD (3.2 MB) |
I-SELECT 2 PLUG PRE / EXC Accessories
Product description
- Ready-for-use resistor to set output current value
- Compatible with LED driver featuring I-select 2 interface; not compatible with I-SELECT (generation 1)
- Resistor is base insulated
- Resistor power 0.25 W
- Current tolerance ± 2 % additional to output current tolerance
- Compatible with LED driver series PRE and EXC
Example of calculation
- R [kΩ] = 5 V / I_out [mA] x 1000
- E96 resistor value used
- Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base insulation necessary
- When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data | |||||||
---|---|---|---|---|---|---|---|
Type | Article number | Colour | Marking | Current | Resistor value | Packaging, bag | Weight per pc. |
I-SELECT 2 PLUG 350MA BL | 28001110 | Blue | 0350 mA | 350 mA | 14.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 375MA BL | 28001111 | Blue | 0375 mA | 375 mA | 13.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 400MA BL | 28001112 | Blue | 0400 mA | 400 mA | 12.40 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 425MA BL | 28001251 | Blue | 0425 mA | 425 mA | 11.80 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 450MA BL | 28001113 | Blue | 0450 mA | 450 mA | 11.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 475MA BL | 28001252 | Blue | 0475 mA | 475 mA | 10.50 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 500MA BL | 28001114 | Blue | 0500 mA | 500 mA | 10.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 525MA BL | 28001960 | Blue | 0525 mA | 525 mA | 9.53 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 550MA BL | 28001115 | Blue | 0550 mA | 550 mA | 9.09 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 600MA BL | 28001116 | Blue | 0600 mA | 600 mA | 8.25 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 650MA BL | 28001117 | Blue | 0650 mA | 650 mA | 7.68 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 700MA BL | 28001118 | Blue | 0700 mA | 700 mA | 7.15 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 750MA BL | 28001119 | Blue | 0750 mA | 750 mA | 6.65 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 800MA BL | 28001120 | Blue | 0800 mA | 800 mA | 6.19 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 850MA BL | 28001121 | Blue | 0850 mA | 850 mA | 5.90 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 900MA BL | 28001122 | Blue | 0900 mA | 900 mA | 5.62 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 950MA BL | 28001123 | Blue | 0950 mA | 950 mA | 5.23 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1000MA BL | 28001124 | Blue | 1000 mA | 1,000 mA | 4.99 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1050MA BL | 28001125 | Blue | 1050 mA | 1,050 mA | 4.75 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Blue | MAX | MAX | 0.00 kΩ | 10 pc(s). | 0.001 kg |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
I-SELECT 2 PLUG 350MA BL | 28001110 | CAD (712.6 KB) |
I-SELECT 2 PLUG 375MA BL | 28001111 | CAD (712.6 KB) |
I-SELECT 2 PLUG 400MA BL | 28001112 | CAD (712.6 KB) |
I-SELECT 2 PLUG 425MA BL | 28001251 | CAD (712.6 KB) |
I-SELECT 2 PLUG 450MA BL | 28001113 | CAD (712.6 KB) |
I-SELECT 2 PLUG 475MA BL | 28001252 | CAD (712.6 KB) |
I-SELECT 2 PLUG 500MA BL | 28001114 | CAD (712.6 KB) |
I-SELECT 2 PLUG 525MA BL | 28001960 | CAD (712.6 KB) |
I-SELECT 2 PLUG 550MA BL | 28001115 | CAD (712.6 KB) |
I-SELECT 2 PLUG 600MA BL | 28001116 | CAD (712.6 KB) |
I-SELECT 2 PLUG 650MA BL | 28001117 | CAD (712.6 KB) |
I-SELECT 2 PLUG 700MA BL | 28001118 | CAD (712.6 KB) |
I-SELECT 2 PLUG 750MA BL | 28001119 | CAD (712.6 KB) |
I-SELECT 2 PLUG 800MA BL | 28001120 | CAD (712.6 KB) |
I-SELECT 2 PLUG 850MA BL | 28001121 | CAD (712.6 KB) |
I-SELECT 2 PLUG 900MA BL | 28001122 | CAD (712.6 KB) |
I-SELECT 2 PLUG 950MA BL | 28001123 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1000MA BL | 28001124 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1050MA BL | 28001125 | CAD (712.6 KB) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712.6 KB) |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
LCA 25W 350-1050mA one4all SC PRE | 28000675 | CAD (704.6 KB) |
EPD | ||
---|---|---|
Type | Article number | Environmental Product Declaration (EPD) |
LCA 25W 350-1050mA one4all SC PRE | 28000675 | EPD |