- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Linear dimming SELV
- ►
- 21 mm premium
- ►
- LCA 50 W 350–1050 mA one4all lp PRE
Driver LCA 50W 350–1050mA one4all lp PRE
21 mm premium series
Product description
- NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
- Dimmable built-in constant current LED driver
- Dimming range 1 to 100 %
- For luminaires of protection class I and protection class II
- Output current adjustable between 350 – 1,050 mA via ready2mains Programmer, I-SELECT 2 plugs or DALI
- Max. output power 50 W
- Up to 91 % efficiency
- Power input on stand-by < 0.15 W
- Nominal lifetime up to 100,000 h
- 5 years guarantee
Housing properties
- Low profile metal casing with white cover
- Type of protection IP20
Interfaces
- one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
- ready2mains (configuration and dimming via mains)
- Terminal blocks: 0° push terminals
Functions
- Adjustable output current in 1-mA-steps (DALI, ready2mains, I-SELECT 2)
- Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
- Constant light output function (CLO)
- Power-up fading at AC
- Configurable via ready2mains
- Switch off the driver with fade2zero
- Service monitor to log certain events
- Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
- Intelligent Voltage Guard (overvoltage and undervoltage monitoring)
- Suitable for emergency escape lighting systems acc. to EN 50172
Benefits
- Flexible configuration via companionSUITE
- Application-oriented operating window for maximum compatibility
- Best energy savings due to low stand-by losses and high efficiency
- Flexible configuration via DALI, ready2mains and I-SELECT 2
- Reliability proven by lifetime up to 100,000 h and 5 years guarantee
Typical applications
- For linear/area lighting in office applications
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LCA 50W 350-1050mA one4all lp PRE | 28000656 | 10 pc(s). | 760 pc(s). | 0.244 kg |
- Luminaire types:
-
-
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. current (at 230 V, 50 Hz, full load) (1) (2) | 102 – 248 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 71.5 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 440 µA |
Max. input power | 56.5 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 91 % |
λ (at 230 V, 50 Hz, full load) (1) | 0.98 |
Typ. power consumption on stand-by (3) | < 0.15 W |
Typ. input current in no-load operation | 33 mA |
Typ. input power in no-load operation | 0.42 W |
In-rush current (peak / duration) | 35 A / 170 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 6.1 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Starting time (DC mode) | < 0.3 s |
Switchover time (AC/DC) (4) | < 0.2 s |
Turn off time (at 230 V, 50 Hz, full load) | < 20 ms |
Output current tolerance (1) (5) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 40 % |
Output LF current ripple (< 120 Hz) | ± 5 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 60 V |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Surge voltage at output side (against PE) | < 0.5 kV |
Type of protection | IP20 |
Lifetime | up to 100,000 h |
Guarantee | 5 Year(s) |
Dimensions L x W x H | 360 x 30 x 21 mm |
Specific technical data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Type | Output current (1) (2) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | Ambient temperature ta | I-SELECT 2 resistor value (3) |
LCA 50W 350-1050mA one4all lp PRE | 350 mA | 20 V | 50 V | 17.5 W | 20.9 W | 102 mA | 85 °C | -25 ... +70 °C | – |
LCA 50W 350-1050mA one4all lp PRE | 400 mA | 20 V | 50 V | 20.0 W | 23.5 W | 112 mA | 85 °C | -25 ... +70 °C | 12.50 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 450 mA | 20 V | 50 V | 22.5 W | 26.2 W | 123 mA | 85 °C | -25 ... +70 °C | 11.11 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 500 mA | 20 V | 50 V | 25.0 W | 28.8 W | 133 mA | 85 °C | -25 ... +70 °C | 10.00 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 550 mA | 20 V | 50 V | 27.5 W | 31.4 W | 144 mA | 85 °C | -25 ... +70 °C | 9.09 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 600 mA | 20 V | 50 V | 30.0 W | 34.0 W | 155 mA | 85 °C | -25 ... +70 °C | 8.33 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 650 mA | 20 V | 50 V | 32.5 W | 36.6 W | 166 mA | 85 °C | -25 ... +70 °C | 7.69 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 700 mA | 20 V | 50 V | 35.0 W | 39.2 W | 177 mA | 85 °C | -25 ... +70 °C | 7.14 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 750 mA | 20 V | 50 V | 37.5 W | 41.9 W | 188 mA | 80 °C | -25 ... +65 °C | 6.67 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 800 mA | 20 V | 50 V | 40.0 W | 44.6 W | 200 mA | 80 °C | -25 ... +65 °C | 6.25 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 850 mA | 20 V | 50 V | 42.5 W | 47.2 W | 211 mA | 80 °C | -25 ... +65 °C | 5.88 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 900 mA | 20 V | 50 V | 45.0 W | 49.9 W | 223 mA | 80 °C | -25 ... +65 °C | 5.56 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 950 mA | 20 V | 50 V | 47.5 W | 52.4 W | 233 mA | 80 °C | -25 ... +65 °C | 5.26 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 1,000 mA | 20 V | 50 V | 50.0 W | 55.3 W | 245 mA | 80 °C | -25 ... +65 °C | 5.00 kΩ |
LCA 50W 350-1050mA one4all lp PRE | 1,050 mA | 20 V | 48 V | 50.0 W | 56.0 W | 248 mA | 80 °C | -25 ... +65 °C | 0.00 kΩ |
Further information
- ready2mains™ (http://www.ready2mains.eu/com/en/products/luxcontrol-ready2mains.asp)
- FAQ – LED systems (http://www.ready2mains.eu/com/en/faq-led.asp)
- Reference projects (http://www.ready2mains.eu/com/en/reference-projects.asp)
- Environmental declarations (http://www.ready2mains.eu/com/en/environmental-declarations.asp)
- Tender text (http://www.ready2mains.eu/com/en/tender.asp)
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |
I-SELECT 2 PLUG PRE / EXC Accessories
Product description
- Ready-for-use resistor to set output current value
- Compatible with LED driver featuring I-select 2 interface; not compatible with I-SELECT (generation 1)
- Resistor is base insulated
- Resistor power 0.25 W
- Current tolerance ± 2 % additional to output current tolerance
- Compatible with LED driver series PRE and EXC
Example of calculation
- R [kΩ] = 5 V / I_out [mA] x 1000
- E96 resistor value used
- Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base insulation necessary
- When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data | |||||||
---|---|---|---|---|---|---|---|
Type | Article number | Colour | Marking | Current | Resistor value | Packaging, bag | Weight per pc. |
I-SELECT 2 PLUG 350MA BL | 28001110 | Blue | 0350 mA | 350 mA | 14.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 375MA BL | 28001111 | Blue | 0375 mA | 375 mA | 13.30 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 400MA BL | 28001112 | Blue | 0400 mA | 400 mA | 12.40 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 425MA BL | 28001251 | Blue | 0425 mA | 425 mA | 11.80 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 450MA BL | 28001113 | Blue | 0450 mA | 450 mA | 11.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 475MA BL | 28001252 | Blue | 0475 mA | 475 mA | 10.50 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 500MA BL | 28001114 | Blue | 0500 mA | 500 mA | 10.00 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 525MA BL | 28001960 | Blue | 0525 mA | 525 mA | 9.53 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 550MA BL | 28001115 | Blue | 0550 mA | 550 mA | 9.09 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 600MA BL | 28001116 | Blue | 0600 mA | 600 mA | 8.25 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 650MA BL | 28001117 | Blue | 0650 mA | 650 mA | 7.68 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 700MA BL | 28001118 | Blue | 0700 mA | 700 mA | 7.15 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 750MA BL | 28001119 | Blue | 0750 mA | 750 mA | 6.65 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 800MA BL | 28001120 | Blue | 0800 mA | 800 mA | 6.19 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 850MA BL | 28001121 | Blue | 0850 mA | 850 mA | 5.90 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 900MA BL | 28001122 | Blue | 0900 mA | 900 mA | 5.62 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 950MA BL | 28001123 | Blue | 0950 mA | 950 mA | 5.23 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1000MA BL | 28001124 | Blue | 1000 mA | 1,000 mA | 4.99 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1050MA BL | 28001125 | Blue | 1050 mA | 1,050 mA | 4.75 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Blue | MAX | MAX | 0.00 kΩ | 10 pc(s). | 0.001 kg |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
I-SELECT 2 PLUG 350MA BL | 28001110 | CAD (712.6 KB) |
I-SELECT 2 PLUG 375MA BL | 28001111 | CAD (712.6 KB) |
I-SELECT 2 PLUG 400MA BL | 28001112 | CAD (712.6 KB) |
I-SELECT 2 PLUG 425MA BL | 28001251 | CAD (712.6 KB) |
I-SELECT 2 PLUG 450MA BL | 28001113 | CAD (712.6 KB) |
I-SELECT 2 PLUG 475MA BL | 28001252 | CAD (712.6 KB) |
I-SELECT 2 PLUG 500MA BL | 28001114 | CAD (712.6 KB) |
I-SELECT 2 PLUG 525MA BL | 28001960 | CAD (712.6 KB) |
I-SELECT 2 PLUG 550MA BL | 28001115 | CAD (712.6 KB) |
I-SELECT 2 PLUG 600MA BL | 28001116 | CAD (712.6 KB) |
I-SELECT 2 PLUG 650MA BL | 28001117 | CAD (712.6 KB) |
I-SELECT 2 PLUG 700MA BL | 28001118 | CAD (712.6 KB) |
I-SELECT 2 PLUG 750MA BL | 28001119 | CAD (712.6 KB) |
I-SELECT 2 PLUG 800MA BL | 28001120 | CAD (712.6 KB) |
I-SELECT 2 PLUG 850MA BL | 28001121 | CAD (712.6 KB) |
I-SELECT 2 PLUG 900MA BL | 28001122 | CAD (712.6 KB) |
I-SELECT 2 PLUG 950MA BL | 28001123 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1000MA BL | 28001124 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1050MA BL | 28001125 | CAD (712.6 KB) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712.6 KB) |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
LCA 50W 350-1050mA one4all lp PRE | 28000656 | CAD (515.0 KB) |
EPD | ||
---|---|---|
Type | Article number | Environmental Product Declaration (EPD) |
LCA 50W 350-1050mA one4all lp PRE | 28000656 | EPD |