- Tridonic
- Products
- LED drivers
- Filter
- Generation 4
- companionSUITE software
- Outdoor compact dimming
- Outdoor linear IP67/IP66 dimming
- Outdoor linear IP67 fixed output
- Industry linear dimming
- Industry linear fixed output
- Linear dimming SELV
- Linear dimming non-SELV
- Linear fixed output SELV
- Linear fixed output non-SELV
- Compact dimming
- Compact fixed output
- in-track dimming
- in-track fixed output
- DC-String
- Constant voltage
- Universal wide voltage (UNV)
- Matter components
- Accessories
- LED modules
- Tunable White
- Emergency Lighting
- Controls and Connectivity
- LED drivers
- Applications
- Connected lighting
- Projects
- Services
- Technical data
- Contact
- Home
- Products
- ►
- LED drivers
- ►
- Linear dimming SELV
- ►
- 21 mm premium
- ►
- LCA 75 W 900–1800 mA one4all lp PRE
Driver LCA 75W 900–1800mA one4all lp PRE
21 mm premium series
Product description
- NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
- Dimmable built-in constant current LED driver
- Dimming range 1 to 100 %
- For luminaires of protection class I and protection class II
- Output current adjustable between 900 – 1,800 mA
- Max. output power 75 W
- Up to 91 % efficiency
- Power input on stand-by < 0.15 W
- Nominal lifetime up to 100,000 h
- 5 years guarantee
Housing properties
- Low profile metal casing with white cover
- Type of protection IP20
Interfaces
- one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
- ready2mains (configuration and dimming via mains)
- Terminal blocks: 0° push terminals
Functions
- Adjustable output current in 1-mA-steps (DALI, ready2mains, I-SELECT 2)
- Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
- Constant light output function (CLO)
- Power-up fading at AC
- Configurable via ready2mains
- Switch off the driver with fade2zero
- Service monitor to log certain events
- Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
- Intelligent Voltage Guard (overvoltage and undervoltage monitoring)
- Suitable for emergency escape lighting systems acc. to EN 50172
Benefits
- Flexible configuration via companionSUITE
- Application-oriented operating window for maximum compatibility
- Best energy savings due to low stand-by losses and high efficiency
- Flexible configuration via DALI, ready2mains and I-SELECT 2
- Reliability proven by lifetime up to 100,000 h and 5 years guarantee
Typical applications
- For linear/area lighting in office applications
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LCA 75W 900-1800mA one4all lp PRE | 28000660 | 10 pc(s). | 760 pc(s). | 0.266 kg |
- Luminaire types:
-
-
-
- Approval marks:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. current (at 230 V, 50 Hz, full load) (1) (2) | 228 – 363 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 50 – 71 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 550 µA |
Max. input power | 83 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 91 % |
λ (at 230 V, 50 Hz, full load) (1) | 0.98 |
Typ. power consumption on stand-by (3) | < 0.15 W |
Typ. input current in no-load operation | 33 mA |
Typ. input power in no-load operation | 0.41 W |
In-rush current (peak / duration) | 34 A / 193 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 8.2 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Starting time (DC mode) | < 0.3 s |
Switchover time (AC/DC) (4) | < 0.3 s |
Turn off time (at 230 V, 50 Hz, full load) | < 4 ms |
Output current tolerance (1) (5) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 40 % |
Output LF current ripple (< 120 Hz) | ± 5 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 60 V |
Dimming range | 1 – 100 % |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Surge voltage at output side (against PE) | < 0.5 kV |
Type of protection | IP20 |
Lifetime | up to 100,000 h |
Guarantee | 5 Year(s) |
Dimensions L x W x H | 360 x 30 x 21 mm |
Specific technical data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Type | Output current (1) (2) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | Ambient temperature ta | I-SELECT 2 resistor value (3) |
LCA 75W 900-1800mA one4all lp PRE | 900 mA | 20 V | 50.0 V | 45.0 W | 50.9 W | 228 mA | 85 °C | -25 ... +65 °C | – |
LCA 75W 900-1800mA one4all lp PRE | 950 mA | 20 V | 50.0 V | 47.5 W | 53.5 W | 241 mA | 85 °C | -25 ... +65 °C | 5.26 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,000 mA | 20 V | 50.0 V | 50.0 W | 56.2 W | 253 mA | 85 °C | -25 ... +65 °C | 5.00 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,050 mA | 20 V | 50.0 V | 52.5 W | 58.6 W | 263 mA | 85 °C | -25 ... +65 °C | 4.76 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,100 mA | 20 V | 50.0 V | 55.0 W | 61.2 W | 274 mA | 85 °C | -25 ... +65 °C | 4.55 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,150 mA | 20 V | 50.0 V | 57.5 W | 63.9 W | 286 mA | 80 °C | -25 ... +60 °C | 4.35 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,200 mA | 20 V | 50.0 V | 60.0 W | 65.4 W | 296 mA | 80 °C | -25 ... +60 °C | 4.17 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,250 mA | 20 V | 50.0 V | 62.5 W | 69.1 W | 308 mA | 80 °C | -25 ... +60 °C | 4.00 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,300 mA | 20 V | 50.0 V | 65.0 W | 71.5 W | 318 mA | 80 °C | -25 ... +60 °C | 3.85 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,350 mA | 20 V | 50.0 V | 67.5 W | 74.1 W | 329 mA | 80 °C | -25 ... +60 °C | 3.70 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,400 mA | 20 V | 50.0 V | 70.0 W | 76.9 W | 341 mA | 80 °C | -25 ... +60 °C | 3.57 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,500 mA | 20 V | 50.0 V | 75.0 W | 82.1 W | 363 mA | 75 °C | -25 ... +55 °C | 3.33 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,600 mA | 20 V | 46.9 V | 75.0 W | 81.6 W | 361 mA | 75 °C | -25 ... +55 °C | 3.13 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,700 mA | 20 V | 44.1 V | 75.0 W | 81.6 W | 361 mA | 75 °C | -25 ... +55 °C | 2.94 kΩ |
LCA 75W 900-1800mA one4all lp PRE | 1,800 mA | 20 V | 41.7 V | 75.0 W | 81.8 W | 362 mA | 75 °C | -25 ... +55 °C | 0.00 kΩ |
Further information
- ready2mains™ (http://www.ready2mains.eu/com/en/products/luxcontrol-ready2mains.asp)
- FAQ – LED systems (http://www.ready2mains.eu/com/en/faq-led.asp)
- Reference projects (http://www.ready2mains.eu/com/en/reference-projects.asp)
- Environmental declarations (http://www.ready2mains.eu/com/en/environmental-declarations.asp)
- Tender text (http://www.ready2mains.eu/com/en/tender.asp)
Reference projects
Certificates / declarations of conformity | ||
Type | Article number | Certificates |
---|---|---|
Certificates () |
I-SELECT 2 PLUG PRE / EXC Accessories
Product description
- Ready-for-use resistor to set output current value
- Compatible with LED driver featuring I-select 2 interface; not compatible with I-SELECT (generation 1)
- Resistor is base insulated
- Resistor power 0.25 W
- Current tolerance ± 2 % additional to output current tolerance
- Compatible with LED driver series PRE and EXC
Example of calculation
- R [kΩ] = 5 V / I_out [mA] x 1000
- E96 resistor value used
- Resistor value tolerance ≤ 1 %; resistor power ≥ 0.1 W; base insulation necessary
- When using a resistor value beyond the specified range, the output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)
Ordering data | |||||||
---|---|---|---|---|---|---|---|
Type | Article number | Colour | Marking | Current | Resistor value | Packaging, bag | Weight per pc. |
I-SELECT 2 PLUG 900MA BL | 28001122 | Blue | 0900 mA | 900 mA | 5.62 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 950MA BL | 28001123 | Blue | 0950 mA | 950 mA | 5.23 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1000MA BL | 28001124 | Blue | 1000 mA | 1,000 mA | 4.99 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1050MA BL | 28001125 | Blue | 1050 mA | 1,050 mA | 4.75 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1100MA BL | 28001126 | Blue | 1100 mA | 1,100 mA | 4.53 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1150MA BL | 28001127 | Blue | 1150 mA | 1,150 mA | 4.32 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1200MA BL | 28001128 | Blue | 1200 mA | 1,200 mA | 4.12 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1250MA BL | 28001129 | Blue | 1250 mA | 1,250 mA | 4.02 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1300MA BL | 28001130 | Blue | 1300 mA | 1,300 mA | 3.83 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1350MA BL | 28001131 | Blue | 1350 mA | 1,350 mA | 3.74 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1400MA BL | 28001132 | Blue | 1400 mA | 1,400 mA | 3.57 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1500MA BL | 28001133 | Blue | 1500 mA | 1,500 mA | 3.32 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1600MA BL | 28001134 | Blue | 1600 mA | 1,600 mA | 3.16 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1700MA BL | 28001135 | Blue | 1700 mA | 1,700 mA | 2.94 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG 1800MA BL | 28001136 | Blue | 1800 mA | 1,800 mA | 2.80 kΩ | 10 pc(s). | 0.001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Blue | MAX | MAX | 0.00 kΩ | 10 pc(s). | 0.001 kg |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
I-SELECT 2 PLUG 900MA BL | 28001122 | CAD (712.6 KB) |
I-SELECT 2 PLUG 950MA BL | 28001123 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1000MA BL | 28001124 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1050MA BL | 28001125 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1100MA BL | 28001126 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1150MA BL | 28001127 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1200MA BL | 28001128 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1250MA BL | 28001129 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1300MA BL | 28001130 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1350MA BL | 28001131 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1400MA BL | 28001132 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1500MA BL | 28001133 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1600MA BL | 28001134 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1700MA BL | 28001135 | CAD (712.6 KB) |
I-SELECT 2 PLUG 1800MA BL | 28001136 | CAD (712.6 KB) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712.6 KB) |
CAD / RAY | ||
---|---|---|
Type | Article number | CAD Files |
LCA 75W 900-1800mA one4all lp PRE | 28000660 | CAD (515.0 KB) |
EPD | ||
---|---|---|
Type | Article number | Environmental Product Declaration (EPD) |
LCA 75W 900-1800mA one4all lp PRE | 28000660 | EPD |