Driver LCO 60W 200–1050mA 100V pD+ NFC C PRE3

premium D4i NFC outdoor series

Product description

  • Dimmable built-in constant current LED driver
  • Dimming range 1 to 100 % (min. 10 mA)
  • For luminaires of protection class I and protection class II
  • Temperature protection as per EN 61347-2-13 C5e
  • Output current adjustable between 200 – 1,050 mA via NFC, DALI or ready2mains Programmer
  • Max. output power 60 W
  • Up to 91.4 % efficiency
  • Lowest power input on stand-by < 0.3 W
  • Nominal lifetime of 100,000 h and 8 years guarantee

Interfaces

  • Near field communication (NFC)
  • Powered DALI-2
  • ready2mains (configuration via mains)
  • U6Me2 (configuration of chronoSTEP via mains and ready2mains Programmer)
  • Terminal blocks: 45° push terminals

Functions

  • Adjustable output current in 1-mA-steps (NFC, DALI, ready2mains)
  • Programmable chronoSTEP: times and levels (NFC, DALI, U6Me2)
  • Enhanced constant light output function (eCLO)
  • Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
  • Intelligent Temperature Guard (ITG)
  • Intelligent Voltage Guard Plus (IVG+)
  • Configurable external temperature management (ETM)
  • Auxiliary 24 V, 3 W power supply
  • DiiA/Zhaga connectivity extensions DT49, DT50, DT51, DT52

Benefits

  • Flexible configuration via companionSUITE (NFC, DALI, ready2mains™) or U6Me2 programmer
  • Operating window for maximum compatibility
  • Best energy savings due to low stand-by losses and high efficiency
  • In-field programming possible after installation with NFC interface and ready2mains
  • High overvoltage protection: up to 10 kV asymmetric (protection class I and II)

Typical applications

  • Road, street and industry
Autoscroll for tables
Ordering data
Type Article number Pack­ag­ing, carton Pack­ag­ing, pallet Weight per pc.
LCO 60/200-1050/100 pD+ NF C PRE3 87500831 20 pc(s). 240 pc(s). 0.303 kg
LCO 60/200-1050/100 pD+ NF C PRE3 28004663 20 pc(s). 1 pc(s). 0.325 kg
Luminaire types:
Street lanterns
Approval marks:
D4i
Zhaga NFC
NFC
DALI-2
IP20
130
Short Circuit Proof without safety insulation
doppelte Isolierung
r2m
Emergency Lighting suitable
BIS
EAC
KC
CCC
RCM
CE
UKCA
ENEC
RoHs
Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. rated current (at 230 V, 50 Hz, full load) (1) (2) 380 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 60 mA
Leakage current (at 230 V, 50 Hz, full load) (1) (2) < 500 µA
Touch current (equipotential connected) (3) 500 µA
Max. input power 77 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) (4) 91.4 %
λ (at 230 V, 50 Hz, full load) (1) 0.97
Typ. power consumption on stand-by (5) < 0.3 W
In-rush current (peak / duration) 28.4 A / 270 µs
THD (at 230 V, 50 Hz, full load) (1) < 8 %
Starting time (AC mode) < 750 ms
Starting time (DC mode) < 650 ms
Switchover time (AC/DC) < 300 ms
Turn off time (at 230 V, 50 Hz, full load) < 500 ms
Output current tolerance (1) (6) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 15 %
Output LF current ripple (< 120 Hz) ± 3.3 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 130 V
Max. output voltage (HV) 130 V
Max. output voltage (LV) 80 V
Dimming range 1 – 100 %
Mains surge capability (between L - N) (7) 6 kV / 3 kA
Mains surge capability (between L/N - PE) 10 kV
Burst protection 6 kV
Surge voltage at output side (against PE) < 1 kV
Type of protection IP20
Lifetime up to 100,000 h
Guarantee 8 Year(s)
Dimensions L x W x H 133 x 77 x 31 mm
Autoscroll for tables
Specific technical data
Type Output current (1) Min. output voltage Max. output voltage Max. output power Typ. power con­sump­tion (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) tc point max. Ambient temperature ta
High voltage output (HV)
LCO 60/200-1050/100 pD+ NF C PRE3 200 mA 48.0 V 100.0 V 20.0 W 23.9 W 113 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 250 mA 47.0 V 100.0 V 25.0 W 29.1 W 133 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 300 mA 47.0 V 100.0 V 30.0 W 34.3 W 155 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 350 mA 47.0 V 100.0 V 35.0 W 39.5 W 177 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 400 mA 47.0 V 100.0 V 40.0 W 44.7 W 199 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 450 mA 47.0 V 100.0 V 45.0 W 50.0 W 222 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 500 mA 47.0 V 100.0 V 50.0 W 55.4 W 245 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 550 mA 47.0 V 100.0 V 55.0 W 60.7 W 268 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 600 mA 47.0 V 100.0 V 60.0 W 66.0 W 291 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 650 mA 47.0 V 92.3 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 700 mA 47.0 V 85.7 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 750 mA 47.0 V 80.0 V 60.0 W 65.7 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 800 mA 47.0 V 75.0 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 850 mA 47.0 V 70.6 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 900 mA 47.0 V 66.7 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 950 mA 47.0 V 63.2 V 60.0 W 65.9 W 291 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,000 mA 47.0 V 60.0 V 60.0 W 65.9 W 291 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,050 mA 47.0 V 57.1 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 200 mA 48.0 V 100.0 V 20.0 W 23.9 W 113 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 250 mA 47.0 V 100.0 V 25.0 W 29.1 W 133 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 300 mA 47.0 V 100.0 V 30.0 W 34.3 W 155 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 350 mA 47.0 V 100.0 V 35.0 W 39.5 W 177 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 400 mA 47.0 V 100.0 V 40.0 W 44.7 W 199 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 450 mA 47.0 V 100.0 V 45.0 W 50.0 W 222 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 500 mA 47.0 V 100.0 V 50.0 W 55.4 W 245 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 550 mA 47.0 V 100.0 V 55.0 W 60.7 W 268 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 600 mA 47.0 V 100.0 V 60.0 W 66.0 W 291 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 650 mA 47.0 V 92.3 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 700 mA 47.0 V 85.7 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 750 mA 47.0 V 80.0 V 60.0 W 65.7 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 800 mA 47.0 V 75.0 V 60.0 W 65.8 W 290 mA 85 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 850 mA 47.0 V 70.6 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 900 mA 47.0 V 66.7 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 950 mA 47.0 V 63.2 V 60.0 W 65.9 W 291 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,000 mA 47.0 V 60.0 V 60.0 W 65.9 W 291 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,050 mA 47.0 V 57.1 V 60.0 W 65.8 W 290 mA 90 °C -40 ... +60 °C
Low voltage output (LV)
LCO 60/200-1050/100 pD+ NF C PRE3 200 mA 48.0 V 59.0 V 11.8 W 15.5 W 78 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 250 mA 38.4 V 59.0 V 14.8 W 18.6 W 90 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 300 mA 32.0 V 59.0 V 17.7 W 21.6 W 103 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 350 mA 28.0 V 59.0 V 20.7 W 24.7 W 115 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 400 mA 28.0 V 59.0 V 23.6 W 27.8 W 128 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 450 mA 28.0 V 59.0 V 26.6 W 31.0 W 141 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 500 mA 28.0 V 59.0 V 29.5 W 34.1 W 154 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 550 mA 28.0 V 59.0 V 32.5 W 37.2 W 167 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 600 mA 28.0 V 59.0 V 35.4 W 40.2 W 180 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 650 mA 28.0 V 59.0 V 38.4 W 43.3 W 193 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 700 mA 28.0 V 59.0 V 41.3 W 46.4 W 207 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 750 mA 28.0 V 59.0 V 44.3 W 49.6 W 221 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 800 mA 28.0 V 59.0 V 47.2 W 52.8 W 234 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 850 mA 28.0 V 59.0 V 50.2 W 56.1 W 248 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 900 mA 28.0 V 59.0 V 53.1 W 59.2 W 262 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 950 mA 28.0 V 59.0 V 56.1 W 62.4 W 276 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,000 mA 28.0 V 59.0 V 59.0 W 65.6 W 290 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,050 mA 28.0 V 57.1 V 60.0 W 66.6 W 294 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 200 mA 48.0 V 59.0 V 11.8 W 15.5 W 78 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 250 mA 38.4 V 59.0 V 14.8 W 18.6 W 90 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 300 mA 32.0 V 59.0 V 17.7 W 21.6 W 103 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 350 mA 28.0 V 59.0 V 20.7 W 24.7 W 115 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 400 mA 28.0 V 59.0 V 23.6 W 27.8 W 128 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 450 mA 28.0 V 59.0 V 26.6 W 31.0 W 141 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 500 mA 28.0 V 59.0 V 29.5 W 34.1 W 154 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 550 mA 28.0 V 59.0 V 32.5 W 37.2 W 167 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 600 mA 28.0 V 59.0 V 35.4 W 40.2 W 180 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 650 mA 28.0 V 59.0 V 38.4 W 43.3 W 193 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 700 mA 28.0 V 59.0 V 41.3 W 46.4 W 207 mA 90 °C -40 ... +65 °C
LCO 60/200-1050/100 pD+ NF C PRE3 750 mA 28.0 V 59.0 V 44.3 W 49.6 W 221 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 800 mA 28.0 V 59.0 V 47.2 W 52.8 W 234 mA 90 °C -40 ... +60 °C
LCO 60/200-1050/100 pD+ NF C PRE3 850 mA 28.0 V 59.0 V 50.2 W 56.1 W 248 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 900 mA 28.0 V 59.0 V 53.1 W 59.2 W 262 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 950 mA 28.0 V 59.0 V 56.1 W 62.4 W 276 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,000 mA 28.0 V 59.0 V 59.0 W 65.6 W 290 mA 90 °C -40 ... +55 °C
LCO 60/200-1050/100 pD+ NF C PRE3 1,050 mA 28.0 V 57.1 V 60.0 W 66.6 W 294 mA 90 °C -40 ... +55 °C
Document Size Date  
 
Driver_LCO_60W_200-1050mA_100V_pDplus_NF_C_PRE3_en.pdf
Data sheet
3.15 MB 17/10/2023
Function_overview_LED_drivers_en.pdf
LED drivers – Functional description
3.35 MB 18/01/2024
NFC_readers_companionSUITE.pdf
NFC readers/writers supported by companionSUITE
5.95 MB 14/02/2023
Outdoor_smart_booklet_2022_EN.pdf
Smart booklet – Outdoor
7.73 MB 04/07/2023
SIDEREA_smart_booklet_EN.pdf
SIDEREA – Smart booklet
4.74 MB 11/05/2023
Certificates / declarations of conformity
Type      Article number      Certificates     
Certificates ()
Autoscroll for tables
CAD / RAY
Type Article number CAD Files
LCO 60/200-1050/100 pD+ NF C PRE3 87500831 CAD (8.7 MB)
EPD
Type Article number Environmental Product Declaration (EPD)
LCO 60/200-1050/100 pD+ NF C PRE3 87500831 EPD
 
 
Visiting from the US or Canada?
Go to our dedicated site.
http://www.tridonic.us or stay on tridonic.com